PTG series filter cartridge is made of hydrophobic PTFE membrane and inherently hydrophobic PTFE membrane ensuring the sterilizing performance in different humidity environments. The PP components offer superior oxidation resistance. The reinforced core makes the filter cartridges have higher pressure resistance to withstand, The in-line steam sterilization and autoclave., it is suitable for fermentation, pharmaceutical, and other biotechnology applications.
Features |
|
Applications |
|
Dimension | |
Length | 5” (125mm) / 10” (254mm) / 20” (500mm) 30” (750mm) / 40” (1000mm) |
Out Diameter | 69mm (2.72”) |
EFA | 0.8m² / 10” |
Material of Constructions | |
Membranes | Inherently hydrophobic PTFE |
Support/Drainage | Oxidation resistant PP |
Cage/Core/Endcap | Oxidation resistant PP |
O-ring | Please refer to ordering information |
Removal Efficiency | |
0022 | Gas: 0.01μm Liquid: 0.2μm |
Operating Conditions | |
Maximum differential pressure | 5.2Bar@20℃ |
Maximum operating temperature | 2.4Bar@80℃ |
Sterilization | |
Inline Steam Sterilization: | 135℃/30min, 150 cycles |
Maximum Forward Steam Sterilization: | 1Bar@125℃ 0.3Bar@142℃ |
Maximum Reverse Steam Sterilization: | 0.5Bar@125℃ 0.2Bar@142℃ |
|
Integrity Test Parameters | |
Bubble Point (BP) | ≥1.1Bar@IPA: Water 60:40 |
Diffusion Flow (DF) | PTGP≤16ml / min@1035mbar PTGW≤24ml / min@1035mbar |
Water Instrusion (WIT) | PTGP≤0.38ml / min@2500mbar PTGW≤0.75ml / min@2500mbar |
Quality |
|
Dimensions |
|
Ordering Information |
|